- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Function | 3-Position Spring Centered |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| EN Code | None |
| Seal Material | Buna-N |
| Spool Code | 6 |
| Actuator Type | Solenoid |
| Leakage | Standard Performance |
| Actuation Identification | Solenoid A, Solenoid B |
| Response Type | Standard Response |
| Indicator Lights | Yes |
| Mechanical Options | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Solenoid Energization Code | None |
| Electrical Options | None |
| Model No. | DG5V-8-S-6C-M-FTWL-B-10 |
| Operation | Pilot Operated |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Design No. | 10 |
| Electrical Connection | Wired Terminal Block |
| Solenoid | Double |
| Manual Override Option Code | None |
| Valve Type | Standard-Duty |
| Coil Type Code | F |
| Coil Rating Code | B |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Surge Suppressor/Damper | None |
| Spool Spring Arrangement Code | C |
| Electrical Connector Code | T |
| Housing Code | W |
| Pressure Port Check Valve Code | None |
| Pressure [Max] | 5000 psi |
| Center Position | P Blocked, A & B to T |
| Gauge Port | SAE-4 |
| Pilot Drain Code | None |
| Gauge Ports Code | None |
| Spool Control Modification Code | None |
| NFPA Size | D08 |
| AC/DC | AC |
| Reducer Module | No |
| Solenoid Indicator Lights Code | L |
| Mechanical Options Code | None |
| Body Material | Ductile Iron |
| Pilot Pressure Code | None |
| Spool Indicator Switch Code | None |
| Tank Port Rating | 5000 |
| Response Type Code | None |
| Pressure Port Check Valve Pressure | N/A |
| Performance | Standard Performance |
| Temperature Range [Min] | -40 °F |
| No. of Stages | Two Stage |
| Fluid Cleanliness | 19/17/14 micron |
| Port Restrictor Plug Code | None |
| Electrical Options Code | None |
| Reducer Module Code | None |
| Overrides | Plain Override Solenoid Ends |
| Rated Flow [Max] | 175 gal/min |
| Compatible Fluids | Petroleum Oil |
| Mounting | Subplate/Manifold Mount |
| Port T Pressure Rating | 5000 psi |
| Manual Override | Plain Override |
| Spool Center Condition | A Port and Double Offset sensing switch on B Port |
| Pilot Valve Type Code | S |
| Port Restrictor Plugs | None |
| Crossover | P Blocked, A or B to T |
| Surge Suppressor/Damper Code | None |
| Pilot/Drain | External Pilot/Internal Drain |
| Temperature Range [Max] | 230 °F |
| Weight | 35.0 LB |