Vickers by Danfoss02-329163

02-329163

Vickers D08 Solenoid Valve
Item #101978007
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329163
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Mixing grid coupling components from different manufacturers may cause premature failure and possible personal injury or property damage from flying debris
Crossover P Blocked, A or B to T
Tank Port Rating 5000
Temperature Range [Min] -40 °F
Fluid Cleanliness 19/17/14 micron
Spool Indicator Switch Code None
Port Restrictor Plug Code None
Pilot Valve Type CETOP 3, High Performance
Pressure Port Check Valve Pressure N/A
Pressure Port Check Valve Code None
Solenoid Double
Pilot Drain Code T
Spool Code 6
Performance High Performance
Temperature Range [Max] 230 °F
Reducer Module Code None
Model No. DG5V-8-H-6C-E-T-M-FW-B-10
Electrical Options Code None
Indicator Lights No
Body Material Ductile Iron
Mechanical Options Code None
Valve Type Standard-Duty
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port T Pressure Rating 5000 psi
No. of Stages Two Stage
Spool Control Modification Code None
Pressure [Max] 5000 psi
AC/DC AC
Operation Pilot Operated
Mounting Subplate/Manifold Mount
EN Code None
Manual Override Plain Override
Function 3-Position Spring Centered
Surge Suppressor/Damper Code None
Overrides Plain Override Solenoid Ends
Housing Code W
Design No. 10
Gauge Ports Code None
Center Position P Blocked, A & B to T
Actuation Identification Solenoid A, Solenoid B
Electrical Connector Code None
Coil Rating Code B
Response Type Standard Response
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
NFPA Size D08
Coil Type Code F
Spool Spring Arrangement Code C
Actuator Type Solenoid
Pilot Pressure Code E
Surge Suppressor/Damper None
Pilot/Drain External Pilot/Internal Drain
Solenoid Energization Code None
Pilot Valve Type Code H
Electrical Options None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Leakage High Performance
Electrical Connection No Connector
Rated Flow [Max] 175 gal/min
Solenoid Indicator Lights Code None
Mechanical Options None
Response Type Code None
Seal Material Buna-N
Manual Override Option Code None
Port Restrictor Plugs None
Gauge Port SAE-4
Compatible Fluids Petroleum Oil
Reducer Module No
Weight 35.0 LB
We're here for you