Vickers D08 Solenoid Valve
Item #101979716
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329117
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
  • When a drive has three pulleys, at least two should be flanged
  • If the drive has more than three pulleys, every other pulley should be flanged
Electrical Options Code None
Gauge Port SAE-4
Pressure Port Check Valve Pressure N/A
Surge Suppressor/Damper Code None
Design No. 10
Voltage & Frequency 110/120 VAC - 50/60 Hz
Model No. DG5V-8-H-2C-M-FW-B-10
Gauge Ports Code None
Actuator Type Solenoid
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Spool Indicator Switch Code None
Leakage Standard Performance
Port Restrictor Plug Code None
Manual Override Plain Override
Response Type Code None
Operation Pilot Operated
Pilot Valve Type Code H
Port Restrictor Plugs None
Solenoid Energization Code None
Overrides Plain Override Solenoid Ends
Performance High Performance
Pilot Pressure Code None
Seal Material Buna-N
Compatible Fluids Petroleum Oil
Fluid Cleanliness 19/17/14 micron
Indicator Lights No
No. of Stages Two Stage
Response Type Standard Response
Tank Port Rating 5000
Manual Override Option Code None
Reducer Module Code None
EN Code None
Electrical Connection No Connector
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pressure [Max] 5000 psi
Body Material Gray Iron
Valve Type Standard-Duty
Rated Flow [Max] 175 gal/min
AC/DC AC
Reducer Module No
Pressure Port Check Valve Code None
Coil Rating Code B
Pilot Valve Type CETOP 3, High Performance
Coil Type Code F
Center Position All Ports Blocked
Surge Suppressor/Damper None
Crossover All Ports Blocked
Spool Code 2
Spool Control Modification Code None
Mechanical Options None
Pilot/Drain External Pilot/Internal Drain
Spool Spring Arrangement Code C
Mounting Subplate/Manifold Mount
Electrical Options None
Mechanical Options Code None
Solenoid Double
Port T Pressure Rating 5000 psi
Function 3-Position Spring Centered
Solenoid Indicator Lights Code None
NFPA Size D08
Housing Code W
Spool Center Condition A Port and Double Offset sensing switch on B Port
Pilot Drain Code None
Electrical Connector Code None
Weight 35.0 LB