- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Tank Port Rating | 5000 |
| Rated Flow [Max] | 175 gal/min |
| Body Material | Ductile Iron |
| Valve Type | Standard-Duty |
| Temperature Range [Min] | -40 °F |
| Manual Override Option Code | None |
| Gauge Port | SAE-4 |
| Port Restrictor Plug Code | None |
| Pilot Valve Type | CETOP 3, High Performance |
| Solenoid | Double |
| Center Position | All Ports Blocked |
| Electrical Connector Code | T |
| Leakage | High Performance |
| Surge Suppressor/Damper Code | None |
| Design No. | 10 |
| Pilot Valve Type Code | H |
| AC/DC | AC |
| Indicator Lights | Yes |
| Reducer Module | No |
| Pressure Port Check Valve Code | None |
| Response Type | Standard Response |
| No. of Stages | Two Stage |
| Actuator Type | Solenoid |
| Temperature Range [Max] | 230 °F |
| Housing Code | W |
| Performance | High Performance |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Response Type Code | None |
| EN Code | None |
| Electrical Connection | Wired Terminal Block |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Port Restrictor Plugs | None |
| Model No. | DG5V-8-H-2C-M-FTWL-B-10 |
| Mounting | Subplate/Manifold Mount |
| Solenoid Indicator Lights Code | L |
| Seal Material | Buna-N |
| Operation | Pilot Operated |
| Manual Override | Plain Override |
| Pilot Pressure Code | None |
| Coil Rating Code | B |
| Compatible Fluids | Petroleum Oil |
| Gauge Ports Code | None |
| Overrides | Plain Override Solenoid Ends |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Spool Control Modification Code | None |
| Mechanical Options Code | None |
| Surge Suppressor/Damper | None |
| Spool Indicator Switch Code | None |
| Crossover | All Ports Blocked |
| Port T Pressure Rating | 5000 psi |
| NFPA Size | D08 |
| Electrical Options Code | None |
| Spool Spring Arrangement Code | C |
| Pilot Drain Code | None |
| Mechanical Options | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Function | 3-Position Spring Centered |
| Pressure Port Check Valve Pressure | N/A |
| Pressure [Max] | 5000 psi |
| Pilot/Drain | External Pilot/Internal Drain |
| Electrical Options | None |
| Spool Code | 2 |
| Reducer Module Code | None |
| Fluid Cleanliness | 19/17/14 micron |
| Solenoid Energization Code | None |
| Coil Type Code | F |
| Weight | 35.0 LB |