- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Model No. | DG5V-8-S-2C-K-M-FW-B-10 |
| Body Material | Ductile Iron |
| Leakage | Standard Performance |
| Port T Pressure Rating | 5000 psi |
| Electrical Connector Code | None |
| Overrides | Plain Override Solenoid Ends |
| Mechanical Options | None |
| Spool Control Modification Code | None |
| Electrical Options Code | None |
| Pilot Pressure Code | None |
| Temperature Range [Min] | -40 °F |
| Pilot Valve Type Code | S |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Manual Override | Plain Override |
| NFPA Size | D08 |
| Reducer Module | No |
| Indicator Lights | No |
| Function | 3-Position Spring Centered |
| Gauge Ports Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Temperature Range [Max] | 230 °F |
| Spool Code | 2 |
| Surge Suppressor/Damper Code | None |
| Mechanical Options Code | None |
| Valve Type | Standard-Duty |
| Performance | Standard Performance |
| Reducer Module Code | None |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Actuation Identification | Solenoid A, Solenoid B |
| AC/DC | AC |
| Seal Material | Buna-N |
| EN Code | None |
| Pressure Port Check Valve Code | K |
| Spool Spring Arrangement Code | C |
| No. of Stages | Two Stage |
| Rated Flow [Max] | 175 gal/min |
| Fluid Cleanliness | 19/17/14 micron |
| Spool Indicator Switch Code | None |
| Port Restrictor Plugs | None |
| Solenoid Indicator Lights Code | None |
| Pilot Drain Code | None |
| Operation | Pilot Operated |
| Tank Port Rating | 5000 |
| Pilot/Drain | Internal Pilot/External Drain |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Crossover | All Ports Blocked |
| Electrical Connection | No Connector |
| Housing Code | W |
| Mounting | Subplate/Manifold Mount |
| Electrical Options | None |
| Pressure [Max] | 5000 psi |
| Coil Type Code | F |
| Center Position | All Ports Blocked |
| Response Type | Standard Response |
| Solenoid Energization Code | None |
| Pressure Port Check Valve Pressure | 5 psi |
| Actuator Type | Solenoid |
| Response Type Code | None |
| Manual Override Option Code | None |
| Compatible Fluids | Petroleum Oil |
| Gauge Port | SAE-4 |
| Design No. | 10 |
| Coil Rating Code | B |
| Surge Suppressor/Damper | None |
| Port Restrictor Plug Code | None |
| Solenoid | Double |
| Weight | 35.0 LB |