- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Single Solenoid
- 2-Position Spring Offset Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Port T Pressure Rating | 5000 psi |
| Fluid Cleanliness | 19/17/14 micron |
| Performance | Standard Performance |
| Coil Type Code | F |
| Center Position | All Ports Blocked |
| Electrical Options | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Leakage | Standard Performance |
| Mechanical Options Code | None |
| Model No. | DG5V-8-S-2A-T-M-FW-B-10 |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Pressure Port Check Valve Pressure | N/A |
| Indicator Lights | No |
| Coil Rating Code | B |
| Tank Port Rating | 5000 |
| Mechanical Options | None |
| Gauge Port | SAE-4 |
| Temperature Range [Min] | -40 °F |
| Response Type | Standard Response |
| Valve Type | Standard-Duty |
| Electrical Options Code | None |
| NFPA Size | D08 |
| Actuator Type | Solenoid |
| No. of Stages | Two Stage |
| Solenoid Energization Code | None |
| Surge Suppressor/Damper Code | None |
| Compatible Fluids | Petroleum Oil |
| Function | 2-Position Spring Offset |
| Rated Flow [Max] | 175 gal/min |
| Manual Override | Plain Override |
| Body Material | Ductile Iron |
| Pilot Valve Type Code | S |
| Pilot Drain Code | T |
| Mounting | Subplate/Manifold Mount |
| AC/DC | AC |
| Surge Suppressor/Damper | None |
| Actuation Identification | Solenoid B |
| Manual Override Option Code | None |
| Pressure Port Check Valve Code | None |
| EN Code | None |
| Electrical Connector Code | None |
| Temperature Range [Max] | 230 °F |
| Operation | Pilot Operated |
| Electrical Connection | No Connector |
| Pilot/Drain | External Pilot/Internal Drain |
| Solenoid | Single |
| Spool Control Modification Code | None |
| Port Restrictor Plugs | None |
| Pressure [Max] | 5000 psi |
| Overrides | Plain Override Solenoid Ends |
| Design No. | 10 |
| Housing Code | W |
| Response Type Code | None |
| Pilot Pressure Code | None |
| Gauge Ports Code | None |
| Reducer Module | No |
| Port Restrictor Plug Code | None |
| Spool Spring Arrangement Code | A |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Spool Indicator Switch Code | None |
| Spool Center Condition | B Port End |
| Crossover | All Ports Blocked |
| Solenoid Indicator Lights Code | None |
| Seal Material | Buna-N |
| Spool Code | 2 |
| Reducer Module Code | None |
| Weight | 35.0 LB |