Vickers D10 Solenoid Valve
Item #102085114
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-321788
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Tank Port Rating 3000
Pilot Pressure [Max] 3000 psi
Port Restrictor Plug Code None
Operation Pilot Operated
Temperature Range [Min] -0.4 °F
Compatible Fluids Petroleum Oil
Crossover All Ports Blocked
AC/DC AC
Electrical Options Code None
Coil Type Code F
Mechanical Options None
Electrical Options None
Center Position All Ports Blocked
Assembly Code None
Mounting Subplate/Manifold Mount
Indicator Lights No
Pilot/Drain External Pilot/Internal Drain
Function 3-Position Detented
Spool Spring Arrangement Code N
Model No. DG5V-10-S-2N-M-FW-B-10
Solenoid Indicator Lights Code None
EN Code None
Solenoid Double
Port Restrictor Plugs None
No. of Stages Two Stage
Pressure Port Check Valve Code None
Pilot Valve Type CETOP 3, Standard Performance
Response Type Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Actuation Identification Solenoid A, Solenoid B
Performance Standard Performance
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Pilot Valve Type Code S
Rated Flow [Max] 175 gal/min
Fluid Cleanliness 19/17/14 micron
Reducer Module No
Manual Override Option Code None
Temperature Range [Max] 150.8 °F
Surge Suppressor/Damper Code None
Seal Material Buna-N
Electrical Connector Code None
Electrical Connection No Connector
Pilot Pressure Code None
Solenoid Energization Code None
NFPA Size D10
Port T Pressure Rating 3000 psi
Manual Override Plain Override
Pilot Drain Code None
Pressure [Max] 5000 psi
Housing Code W
Reducer Module Code None
Body Material Ductile Iron
Valve Type Standard-Duty
Spool Center Condition A Port and Double Offset sensing switch on B Port
Response Type Standard Response
Coil Rating Code B
Pressure Port Check Valve Pressure N/A
Overrides Plain Override Solenoid Ends
Surge Suppressor/Damper None
Gauge Port SAE-4
Gauge Ports Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Actuator Type Solenoid
Leakage Standard Performance
Design No. 10
Spool Code 2
Spool Control Modification Code None
Weight 100.0 LB