Skip to content Skip to navigation menu
Vickers by Danfoss02-321780

02-321780

Vickers D10 Solenoid Valve
Item #101978225
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-321780
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Pressure [Max] 5000 psi
Solenoid Energization Code None
Response Type Code None
Response Type Standard Response
Electrical Options None
Gauge Port SAE-4
Overrides Plain Override Solenoid Ends
Coil Type DIN 43650
Reducer Module Code None
Port Restrictor Plug Code None
Indicator Lights No
Port Restrictor Plugs None
Spool Code 2
Assembly Code None
AC/DC AC
Coil Type Code U
Spool Control Modification Code None
Seal Material Buna-N
Pilot Drain Code None
Pressure Port Check Valve Code None
Voltage & Frequency 110 VAC - 50 Hz
Actuator Type Solenoid
Crossover All Ports Blocked
Pilot Valve Type Code H
Pilot Pressure Code None
Center Position All Ports Blocked
Gauge Ports Code None
Model No. DG5V-10-H-2C-M-U-A-10
Solenoid Indicator Lights Code None
Manual Override Plain Override
Solenoid Double
Electrical Connector Code None
Surge Suppressor/Damper None
Design No. 10
Function 3-Position Spring Centered
Pilot/Drain External Pilot/Internal Drain
Valve Type Standard-Duty
Manual Override Option Code None
Rated Flow [Max] 290 gal/min
Port T Pressure Rating 3000 psi
Spool Spring Arrangement Code C
Housing Code None
EN Code None
Electrical Connection No Connector
NFPA Size D10
Electrical Options Code None
Tank Port Rating 3000
Pilot Pressure [Max] 3000 psi
Pressure Port Check Valve Pressure N/A
Operation Pilot Operated
Mechanical Options None
Coil Rating Code A
Surge Suppressor/Damper Code None
Pilot Valve Type CETOP 3, High Performance
Reducer Module N/A
Weight 100.0 LB