Vickers by Danfoss02-321668

02-321668

Vickers D10 Solenoid Valve
Item #102086186
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-321668
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Compatible Fluids Petroleum Oil
EN Code None
Coil Rating Code B
Response Type Code None
Function 2-Position Spring Offset
Center Position All Ports Open
Pressure [Max] 5000 psi
Housing Code W
Electrical Options Code None
Electrical Connector Code PA5
Electrical Connection Five Pin Connector
Tank Port Rating 3000
Pilot Pressure [Max] 3000 psi
Temperature Range [Max] 150.8 °F
Indicator Lights Yes
Port T Pressure Rating 3000 psi
Surge Suppressor/Damper Code None
Response Type Standard Response
Manual Override Option Code None
Mechanical Options None
Spool Code 0
Pilot/Drain External Drain
Valve Type Standard-Duty
Seal Material Buna-N
Electrical Options None
No. of Stages Two Stage
AC/DC AC
Gauge Ports Code None
Mounting Subplate/Manifold Mount
Pressure Port Check Valve Pressure N/A
Reducer Module Code None
Pilot Valve Type CETOP 5, Wet Armature
Gauge Port SAE-4
Manual Override Plain Override
Assembly Code None
Model No. DG5V-10-W-OA-E-M-PA5WL-B-10
Surge Suppressor/Damper None
Coil Type Code None
Rated Flow [Max] 175 gal/min
Temperature Range [Min] -0.4 °F
Pilot Valve Type Code W
Port Restrictor Plugs None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Spring Arrangement Code A
Reducer Module N/A
Leakage Standard Performance
Port Restrictor Plug Code None
Pilot Drain Code None
Solenoid Energization Code None
Pressure Port Check Valve Code None
Coil Type No Coil
Design No. 10
Spool Control Modification Code None
NFPA Size D10
Solenoid Single
Fluid Cleanliness 19/17/14 micron
Pilot Pressure Code E
Body Material Ductile Iron
Overrides None
Actuation Identification Solenoid B
Solenoid Indicator Lights Code L
Actuator Type Solenoid
Crossover All Ports Open
Operation Solenoid Operated
Weight 100.0 LB