Vickers D03 Solenoid Valve

02-318554

Vickers D03 Solenoid Valve
Item #102088155
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Operation Solenoid Operated
Electrical Connection Wired Terminal Block
Pressure Port Check Valve Pressure N/A
Pilot/Drain None
Solenoid Code B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Reducer Module N/A
Housing Code W
Solenoid Indicator Lights Code None
Seal Material Buna-N
Function 3-Position Spring Centered
Spool Spring Arrangement Code C
Spool Code 2
Pilot Valve Type N/A
Electrical Connector Code T
Spool Indicator Switch Code None
Solenoid Double
NFPA Size D03
Overrides No Overrides
Port Restrictor Plugs None
Crossover All Ports Blocked
EN Code None
Pressure [Max] 5075 psi
Cycle Rate [Max] N/A
Port Restrictor Plug Code None
Center Position All Ports Blocked
Indicator Lights No
Actuator Type Solenoid
Function Code 2
Surge Suppressor/Damper None
Design No. 60
AC/DC AC
Solenoid Energization Code None
Tank Port Rating 1500
Mechanical Options None
Port T Pressure Rating 1500 psi
Surge Suppressor/Damper Code None
Electrical Options None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Code 5
Coil Rating Code B
Response Type Standard Response
Spool Shift Timing N/A
Coil Type Code F
Manual Override Option Code H
Rated Flow [Max] 10.5 gal/min
Model No. DG4V 3S 2C H M FTW B5 60
Valve Type Standard-Duty
Weight 5.0 LB