Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-310477

Vickers D03 Solenoid Valve
Item #102110927
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Valve Type High-Performance
Function 3-Position Spring Centered
Seal Material Buna-N
Port T Code 7
Spool Spring Arrangement Code C
Crossover P Blocked, A or B to T
Actuator Type Solenoid
Rated Flow [Max] 20 gal/min
Port T Pressure Rating 3000 psi
Surge Suppressor/Damper None
Solenoid Double
Model No. DG4V-3-6C-M-FW-HL7-60
Manual Override Plain Override
Mounting Subplate/Manifold Mount
Cycle Rate [Max] N/A
Body Material Gray Iron
Pilot/Drain None
Temperature Range [Max] 158 °F
Electrical Connector Code None
Overrides No Overrides
Housing Code W
Spool Indicator Switch Code None
Surge Suppressor/Damper Code None
NFPA Size D03
Pilot Valve Type N/A
Pressure [Max] 5000 psi
Fluid Cleanliness 19/17/14 micron
Design No. 60
Solenoid Energization Code None
EN Code None
Compatible Fluids Petroleum Oil
No. of Stages Single Stage
Tank Port Rating 3046
Solenoid Indicator Lights Code None
Pressure Port Check Valve Pressure N/A
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port Restrictor Plug Code None
Temperature Range [Min] -4 °F
Response Type Standard Response
Port Restrictor Plugs None
Spool Shift Timing N/A
Reducer Module No
Solenoid Code HL
Function Code 6
AC/DC DC
Leakage Standard Performance
Electrical Connection No Connector
Indicator Lights No
Electrical Options None
Coil Rating Code HL
Coil Type Code F
Performance High Performance
Actuation Identification Solenoid A, Solenoid B
Manual Override Option Code None
Center Position P Blocked, A & B to T
Voltage & Frequency 24 VDC, Low Power Coil
Mechanical Options None
Operation Solenoid Operated
Spool Code 6
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison