Vickers D03 Solenoid Valve

02-300055

Vickers D03 Solenoid Valve
Item #102087478
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Cycle Rate [Max] N/A
Fluid Cleanliness 19/17/14 micron
Crossover P Blocked, A or B to T
Actuator Type Solenoid
Overrides No Overrides
Surge Suppressor/Damper Code None
Port Restrictor Plugs None
Spool Code 6
Body Material Gray Iron
Rated Flow [Max] 20 gal/min
Voltage & Frequency 110/120 VAC - 50/60 Hz
Electrical Connection No Connector
Performance High Performance
No. of Stages Single Stage
Indicator Lights No
Surge Suppressor/Damper None
Tank Port Rating 3046
EN Code EN21
Design No. 60
Temperature Range [Min] -4 °F
Spool Shift Timing N/A
Seal Material Buna-N
Valve Type High-Performance
Center Position P Blocked, A & B to T
Actuation Identification Solenoid A, Solenoid B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Compatible Fluids Petroleum Oil
AC/DC AC
Housing Code W
Reducer Module No
Temperature Range [Max] 158 °F
Pressure [Max] 5000 psi
Response Type Standard Response
Port T Pressure Rating 3000 psi
Port T Code 6
Electrical Connector Code None
Model No. DG4V-3-6N-M-FW-B6-60-EN21
Solenoid Code B
Port Restrictor Plug Code None
Electrical Options None
Pressure Port Check Valve Pressure N/A
Spool Spring Arrangement Code N
NFPA Size D03
Manual Override Plain Override
Leakage Standard Performance
Operation Solenoid Operated
Manual Override Option Code None
Mechanical Options None
Solenoid Indicator Lights Code None
Coil Rating Code B
Solenoid Double
Pilot/Drain None
Mounting Subplate/Manifold Mount
Solenoid Energization Code None
Spool Indicator Switch Code None
Function 3-Position Detented
Pilot Valve Type N/A
Coil Type Code F
Response Time 15 to 23 ms
Function Code 6
Weight 5.0 LB