Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-157047

Vickers D03 Solenoid Valve
Item #102042450
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
No. of Stages Single Stage
NFPA Size D03
Pilot Valve Type N/A
Solenoid Code HL
Function 3-Position Spring Centered
Body Material Gray Iron
AC/DC DC
Manual Override Waterproof Override
Spool Shift Timing N/A
Indicator Lights No
Voltage & Frequency 24 VDC
Electrical Options None
Temperature Range [Min] -4 °F
Reducer Module No
Spool Spring Arrangement Code C
Pressure Port Check Valve Pressure N/A
Solenoid Indicator Lights Code None
EN Code None
Operation Solenoid Operated
Leakage Standard Performance
Coil Rating Code HL
Manual Override Option Code H
Port Restrictor Plug Code None
Pilot/Drain None
Model No. DG4V-3-6C-H-M-U-HL7-60
Seal Material Buna-N
Housing Code None
Center Position P Blocked, A & B to T
Tank Port Rating 3046
Actuator Type Solenoid
Crossover P Blocked, A or B to T
Valve Type High-Performance
Rated Flow [Max] 20 gal/min
Pressure [Max] 5000 psi
Cycle Rate [Max] N/A
Design No. 60
Mounting Subplate/Manifold Mount
Mechanical Options None
Spool Indicator Switch Code None
Surge Suppressor/Damper Code None
Coil Type Code U
Solenoid Double
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Max] 158 °F
Compatible Fluids Petroleum Oil
Solenoid Energization Code None
Overrides No Overrides
Port T Pressure Rating 3000 psi
Surge Suppressor/Damper None
Electrical Connector Code None
Function Code 6
Coil Type ISO 4400 (Din 43650) Connector
Response Time 28 to 45 ms
Electrical Connection DIN 43650
Fluid Cleanliness 19/17/14 micron
Watt Rating 18 W
Performance Standard Performance
Port Restrictor Plugs None
Port T Code 7
Response Type Standard Response
Spool Center Condition A Port and Double Offset sensing switch on B Port
Spool Code 6
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison