Vickers D03 Solenoid Valve

02-157047

Vickers D03 Solenoid Valve
Item #102042450
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Valve Type High-Performance
Solenoid Energization Code None
Coil Type Code U
Spool Code 6
AC/DC DC
Port T Code 7
Electrical Connection DIN 43650
Leakage Standard Performance
Spool Spring Arrangement Code C
Performance Standard Performance
Mounting Subplate/Manifold Mount
Voltage & Frequency 24 VDC
Coil Type ISO 4400 (Din 43650) Connector
Port T Pressure Rating 3000 psi
Center Position P Blocked, A & B to T
Body Material Gray Iron
Cycle Rate [Max] N/A
Solenoid Code HL
Surge Suppressor/Damper None
Mechanical Options None
Spool Shift Timing N/A
Operation Solenoid Operated
Function Code 6
EN Code None
Port Restrictor Plug Code None
Reducer Module No
Compatible Fluids Petroleum Oil
Temperature Range [Min] -4 °F
Housing Code None
Fluid Cleanliness 19/17/14 micron
No. of Stages Single Stage
Manual Override Option Code H
Solenoid Double
Indicator Lights No
Rated Flow [Max] 20 gal/min
Spool Center Condition A Port and Double Offset sensing switch on B Port
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Max] 158 °F
Manual Override Waterproof Override
Coil Rating Code HL
Model No. DG4V-3-6C-H-M-U-HL7-60
NFPA Size D03
Tank Port Rating 3046
Design No. 60
Spool Indicator Switch Code None
Pressure Port Check Valve Pressure N/A
Watt Rating 18 W
Pilot/Drain None
Function 3-Position Spring Centered
Overrides No Overrides
Electrical Options None
Pilot Valve Type N/A
Solenoid Indicator Lights Code None
Port Restrictor Plugs None
Seal Material Buna-N
Pressure [Max] 5000 psi
Actuator Type Solenoid
Response Time 28 to 45 ms
Response Type Standard Response
Electrical Connector Code None
Surge Suppressor/Damper Code None
Crossover P Blocked, A or B to T
Weight 5.0 LB