Vickers D03 Solenoid Valve

02-157047

Vickers D03 Solenoid Valve
Item #102042450
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Mechanical Options None
NFPA Size D03
Port T Code 7
Solenoid Code HL
Spool Shift Timing N/A
Manual Override Waterproof Override
Voltage & Frequency 24 VDC
Spool Center Condition A Port and Double Offset sensing switch on B Port
Port Restrictor Plugs None
Performance Standard Performance
Function 3-Position Spring Centered
Mounting Subplate/Manifold Mount
Surge Suppressor/Damper Code None
Model No. DG4V-3-6C-H-M-U-HL7-60
Design No. 60
Electrical Connection DIN 43650
Seal Material Buna-N
Surge Suppressor/Damper None
Fluid Cleanliness 19/17/14 micron
Function Code 6
Rated Flow [Max] 20 gal/min
Pressure Port Check Valve Pressure N/A
Watt Rating 18 W
Pilot Valve Type N/A
Spool Code 6
Solenoid Energization Code None
Temperature Range [Min] -4 °F
Spool Spring Arrangement Code C
Spool Indicator Switch Code None
Tank Port Rating 3046
Indicator Lights No
Compatible Fluids Petroleum Oil
Response Time 28 to 45 ms
Body Material Gray Iron
Leakage Standard Performance
Pressure [Max] 5000 psi
Coil Rating Code HL
Actuation Identification Solenoid A, Solenoid B
AC/DC DC
Reducer Module No
Manual Override Option Code H
Solenoid Indicator Lights Code None
Valve Type High-Performance
Electrical Options None
EN Code None
Operation Solenoid Operated
Overrides No Overrides
Electrical Connector Code None
Crossover P Blocked, A or B to T
Response Type Standard Response
Port Restrictor Plug Code None
Actuator Type Solenoid
Coil Type ISO 4400 (Din 43650) Connector
Temperature Range [Max] 158 °F
Port T Pressure Rating 3000 psi
Housing Code None
Cycle Rate [Max] N/A
Coil Type Code U
Solenoid Double
Center Position P Blocked, A & B to T
Pilot/Drain None
No. of Stages Single Stage
Weight 5.0 LB