Vickers D03 Solenoid Valve

02-147430

Vickers D03 Solenoid Valve
Item #102039441
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Port Restrictor Plug Code None
Body Material Gray Iron
Fluid Cleanliness 19/17/14 micron
Voltage & Frequency 24 VDC
Function 2-Position Spring Offset, Left Hand Build
Tank Port Rating 3046
Spool Spring Arrangement Code A
Solenoid Indicator Lights Code L
Coil Type Code F
NFPA Size D03
Performance High Performance
Temperature Range [Max] 158 °F
Mounting Subplate/Manifold Mount
Reducer Module No
Compatible Fluids Petroleum Oil
Leakage Standard Performance
AC/DC DC
Valve Type High-Performance
Indicator Lights Yes
Spool Shift Timing N/A
Electrical Connector Code T
Temperature Range [Min] -4 °F
Design No. 60
Solenoid Single
Function Code 2
Crossover All Ports Blocked
Housing Code W
Manual Override Option Code None
Response Time 28 to 45 ms
Actuation Identification Solenoid A
Mechanical Options None
Overrides No Overrides
Manual Override Plain Override
Center Position All Ports Blocked
Surge Suppressor/Damper None
Operation Solenoid Operated
Pressure [Max] 5000 psi
Model No. DG4V 3 2AL M FTWL HL7 60
Pilot/Drain None
EN Code None
Port T Pressure Rating 3000 psi
Seal Material Buna-N
Actuator Type Solenoid
Solenoid Energization Code None
Pressure Port Check Valve Pressure N/A
Response Type Standard Response
Solenoid Code HL
Electrical Options None
Port Restrictor Plugs None
Spool Indicator Switch Code None
Surge Suppressor/Damper Code None
Electrical Connection Wired Terminal Block
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Rated Flow [Max] 20 gal/min
Spool Code 2
Watt Rating 18 W
Cycle Rate [Max] N/A
Port T Code 7
Coil Rating Code HL
No. of Stages Single Stage
Pilot Valve Type N/A
Weight 5.0 LB