Vickers D03 Solenoid Valve

02-146800

Vickers D03 Solenoid Valve
Item #102086784
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Model No. DG4V 3 2A M FW B6 60 A08
Crossover All Ports Blocked
Leakage Standard Performance
Solenoid Single
Mounting Subplate/Manifold Mount
Surge Suppressor/Damper None
Pilot/Drain None
Actuation Identification Solenoid B
Housing Code W
Spool Code 2
Tank Port Rating 3046
Surge Suppressor/Damper Code None
Mechanical Options None
Overrides No Overrides
Function 2-Position Spring Offset, End to End
Spool Spring Arrangement Code A
Electrical Connector Code None
Pilot Valve Type N/A
Response Type Standard Response
Solenoid Energization Code None
Spool Indicator Switch Code None
Coil Rating Code B
AC/DC AC
Temperature Range [Min] -4 °F
Port T Code 6
Fluid Cleanliness 19/17/14 micron
Reducer Module No
Temperature Range [Max] 158 °F
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port T Pressure Rating 3000 psi
Actuator Type Solenoid
Response Time 15 to 23 ms
Solenoid Indicator Lights Code None
Pressure Port Check Valve Pressure N/A
Cycle Rate [Max] N/A
EN Code None
Operation Solenoid Operated
Spool Shift Timing N/A
Port Restrictor Plug Code A08
Manual Override Option Code None
Coil Type Code F
Compatible Fluids Petroleum Oil
Solenoid Code B
Design No. 60
NFPA Size D03
Body Material Gray Iron
Electrical Connection No Connector
Valve Type High-Performance
Voltage & Frequency 110/120 VAC - 50/60 Hz
Indicator Lights No
Rated Flow [Max] 20 gal/min
Performance High Performance
No. of Stages Single Stage
Port Restrictor Plugs 0.8 mm Diameter - A Port
Electrical Options None
Manual Override Plain Override
Seal Material Buna-N
Pressure [Max] 5000 psi
Center Position All Ports Blocked
Function Code 2
Weight 5.0 LB