Vickers D03 Solenoid Valve

02-144938

Vickers D03 Solenoid Valve
Item #102096625
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

features

  • These valves conform to ISO 4401 size 03, ANSI/B93.7M size D03, CETOP size 3 and NG 6
Spool Shift Timing N/A
Mechanical Options None
Pressure Port Check Valve Pressure N/A
Port Restrictor Plug Code None
Solenoid Indicator Lights Code None
Operation Solenoid Operated
Solenoid Energization Code V
Electrical Connector Code None
Body Material Gray Iron
Coil Type Code U
Compatible Fluids Phosphate Ester Fluids
Tank Port Rating 3000
Pilot Valve Type N/A
Spool Center Condition A Port and Double Offset sensing switch on B Port
Function Code 8
Port T Code 6
Coil Type ISO 4400 (Din 43650) Connector
Spool Code 8
Leakage Standard Performance
Indicator Lights No
Cycle Rate [Max] 0
EN Code None
Actuator Type Solenoid
Manual Override Plain Override
Model No. DG4V-3-8C-VM-U-B6-61
Surge Suppressor/Damper None
Surge Suppressor/Damper Code None
Design No. 61
Watt Rating 20 W
Function 3-Position, 4-Way, Spring Centered
Pilot/Drain None
Port Restrictor Plugs None
Port T Pressure Rating 3000 psi
Valve Type High-Performance
Spool Indicator Switch Code None
Seal Material Viton
Electrical Connection DIN 43650
Pressure [Max] 5,075 psi
Spool Spring Arrangement Code C
Voltage & Frequency 110/120 VAC - 50/60 Hz
Center Position P to T, A & B Blocked
Response Type Standard Response
Performance Standard Performance
Temperature Range [Min] -4 °F
Reducer Module No
NFPA Size D03
Electrical Options None
Mounting Manifold Mount
Fluid Cleanliness 19/17/14 micron
Manual Override Option Code None
Solenoid Code B
Overrides No Overrides
Rated Flow 21.00 gal/min
Crossover All Ports Open, Restricted
Rated Flow [Max] 20.00 gal/min
Coil Rating Code B
Manufacturer Part No. DG4V 3 8C V M U B6 61
AC/DC AC
Solenoid Double
No. of Stages Single Stage
Housing Code None
Temperature Range [Max] 158 °F
Weight 4.6 LB