- Solenoid Actuated Valve
- Solenoid Operated Operation
- D05 NFPA Size
- Single Solenoid
- 2-Position Spring Centered, End To Center Function
description
- DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
- Port connections are made by mounting the valve on a manifold or subplate containing the interface.
- Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Overrides | No Overrides |
| Temperature Range [Max] | 122 °F |
| Coil Rating Code | B |
| Temperature Range [Min] | 68 °F |
| No. of Stages | Single Stage |
| Seal Material | Buna-N |
| Mechanical Options | None |
| Pressure Port Check Valve Pressure | N/A |
| Solenoid | Single |
| Tank Port Rating | 1000 |
| Indicator Lights | No |
| Pilot/Drain | None |
| Port Restrictor Plugs | None |
| Actuation Identification | Solenoid B |
| Surge Suppressor/Damper | None |
| Model No. | DG4S4-010B-U-B-60 |
| AC/DC | AC |
| Actuator Type | Solenoid |
| Operation | Solenoid Operated |
| Compatible Fluids | Petroleum Oil |
| Manual Override | Plain Override |
| Fluid Cleanliness | 19/17/14 micron |
| Coil Type Code | U |
| Cycle Rate [Max] | N/A |
| Mounting | Subplate/Manifold Mount |
| Pressure [Max] | 6500 psi |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Performance | Standard Performance |
| Electrical Options | None |
| Flow Direction Code | 4 |
| Design No. | 60 |
| Spool Code | 0 |
| Reducer Module | N/A |
| Pilot Valve Type | N/A |
| Body Material | Gray Iron |
| Electrical Connection | DIN 43650 |
| Port T Pressure Rating | 1000 psi |
| Rated Flow [Max] | 24 gal/min |
| Leakage | Standard Performance |
| Center Position | All Ports Open |
| NFPA Size | D05 |
| Response Time | 20 to 40 ms |
| Crossover | All Ports Open |
| Electrical Options Code | None |
| Response Type | Standard Response |
| Function | 2-Position Spring Centered, End To Center |
| Spool Spring Arrangement Code | B |
| Valve Type | Standard-Duty |
| Coil Type | ISO 4400 |
| Mechanical Options Code | None |
| Weight | 10.0 LB |