Vickers D03 Solenoid Valve

02-138081

Vickers D03 Solenoid Valve
Item #101994688
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Port T Code 7
Voltage & Frequency 24 VDC
Function 2-Position Spring Offset, End to Center
Temperature Range [Max] 158 °F
Spool Shift Timing N/A
Port Restrictor Plugs None
NFPA Size D03
Reducer Module No
Indicator Lights No
Fluid Cleanliness 19/17/14 micron
Body Material Gray Iron
Function Code 6
Response Time 28 to 45 ms
Valve Type High-Performance
Pilot/Drain None
Electrical Connection No Connector
Electrical Connector Code None
Performance High Performance
Mechanical Options None
Coil Rating Code H
Housing Code W
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Temperature Range [Min] -4 °F
Spool Code 6
Compatible Fluids Petroleum Oil
Operation Solenoid Operated
Overrides No Overrides
Design No. 60
Cycle Rate [Max] N/A
Manual Override Plain Override
Actuator Type Solenoid
AC/DC DC
Actuation Identification Solenoid B
Solenoid Single
Port T Pressure Rating 3000 psi
Coil Type Code F
Crossover P Blocked, A or B to T
Watt Rating 30 W
Model No. DG4V 3 6B M FW H7 60
Solenoid Code H
Tank Port Rating 3046
Electrical Options None
Surge Suppressor/Damper None
Pressure [Max] 5000 psi
Port Restrictor Plug Code None
EN Code None
Spool Spring Arrangement Code B
No. of Stages Single Stage
Manual Override Option Code None
Leakage Standard Performance
Seal Material Buna-N
Rated Flow [Max] 20 gal/min
Pressure Port Check Valve Pressure N/A
Spool Indicator Switch Code None
Response Type Standard Response
Center Position P Blocked, A & B to T
Pilot Valve Type N/A
Solenoid Indicator Lights Code None
Mounting Subplate/Manifold Mount
Solenoid Energization Code None
Surge Suppressor/Damper Code None
Weight 5.0 LB