Vickers D03 Solenoid Valve

02-137912

Vickers D03 Solenoid Valve
Item #101983291
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Surge Suppressor/Damper Code None
NFPA Size D03
Manual Override Option Code None
Housing Code None
Actuator Type Solenoid
Pilot/Drain None
Cycle Rate [Max] N/A
Seal Material Buna-N
Body Material Gray Iron
Spool Indicator Switch Code None
Overrides No Overrides
Port T Code 7
Pressure [Max] 5000 psi
Response Time 28 to 45 ms
Compatible Fluids Petroleum Oil
Performance Standard Performance
Fluid Cleanliness 19/17/14 micron
Spool Center Condition A Port and Double Offset sensing switch on B Port
Design No. 60
Manual Override Plain Override
Port Restrictor Plugs None
Crossover All Ports Blocked
Reducer Module No
Mounting Subplate/Manifold Mount
Solenoid Code HL
Solenoid Double
Voltage & Frequency 24 VDC
Surge Suppressor/Damper None
Temperature Range [Max] 158 °F
Model No. DG4V 3 2N M U HL7 60
Function Code 2
Pilot Valve Type N/A
Solenoid Energization Code None
Electrical Options None
Temperature Range [Min] -4 °F
AC/DC DC
Port T Pressure Rating 3000 psi
Rated Flow [Max] 20 gal/min
Coil Type ISO 4400 (Din 43650) Connector
Spool Code 2
Coil Rating Code HL
Coil Type Code U
Pressure Port Check Valve Pressure N/A
Valve Type High-Performance
Watt Rating 18 W
Actuation Identification Solenoid A, Solenoid B
Electrical Connector Code None
No. of Stages Single Stage
Operation Solenoid Operated
Spool Spring Arrangement Code N
Indicator Lights No
Port Restrictor Plug Code None
Function 3-Position Detented
Center Position All Ports Blocked
Response Type Standard Response
Leakage Standard Performance
Electrical Connection DIN 43650
EN Code None
Mechanical Options None
Tank Port Rating 3046
Spool Shift Timing N/A
Solenoid Indicator Lights Code None
Weight 5.0 LB