Vickers D07 Solenoid Valve
Item #102007687
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-134527
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D07 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • Two-stage directional valves with an integrally mounted DG4V-3(S)-60 pilot valve. These valves are generally used to control the direction of flow in a hydraulic circuit. This in turn would control the movement of a work cylinder or the rotation of a fluid motor.

applications

  • Suitable for the most demanding industrial applications with flow capacities up to 227 l/min (60 U.S. gpm) and rated pressure of 210 bar (3,000 psi)

features

  • Solid cast body and core passages for maximum strength and minimal pressure drop
Coil Rating Code B
Pressure [Max] 3000 psi
Rated Flow [Max] 60 gal/min
Crossover All Ports Open, Restricted
Design No. 60
Pressure Port Check Valve Pressure N/A
Spool Control Modification Code None
Surge Suppressor/Damper None
Solenoid Energization Code V
Response Type Standard Response
Pilot Valve Type N/A
Valve Type Standard-Duty
Electrical Options Code None
Reducer Module N/A
Seal Material Buna-N
Port T Pressure Rating 1450 psi
Spool Code 8
Pilot Pressure Code E
Assembly Code None
Response Type Code None
Tank Port Rating 1450
Actuation Identification Solenoid A, Solenoid B
Housing Code W
Fluid Cleanliness 19/17/14 micron
EN Code None
Port Restrictor Plugs None
Pilot Valve Tank Pressure Rating Code 5
Body Material Gray Iron
Pilot/Drain External Drain
Electrical Options None
Mounting Screw Option Code N/A
Solenoid Double
Center Position P to T, A & B Blocked
Compatible Fluids Petroleum Oil
Manual Override Option Code None
Solenoid Indicator Lights Code None
Spool Spring Arrangement Code C
Pressure Port Check Valve Code None
Operation Solenoid Operated
Electrical Connection No Connector
Coil Type 1/2 in NPT Thread Wiring Housing
NFPA Size D07
Leakage Standard Performance
Mounting Subplate/Manifold Mount
Electrical Connector Code None
Function 3-Position Spring Centered
Indicator Lights No
Manual Override Plain Override
Mechanical Options None
Actuator Type Solenoid
AC/DC AC
Model No. DG5S4-048C-E-VM-FW-B5-60
Spool Indicator Switch Code None
Coil Type Code F
Port Restrictor Plug Code None
Overrides Plain Override Solenoid Ends
Voltage & Frequency 110/120 VAC - 50/60 Hz
No. of Stages Two Stage
Performance Standard Performance
Pilot Drain Code None
Weight 15.0 LB