Skip to content Skip to navigation menu
Vickers by Danfoss02-126883

02-126883

Vickers D05 Solenoid Valve
Item #101984866
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-126883
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.
  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.

caution

  • Aluminum housings can be used for pressures up to 3,000 psi
  • Steel housings must be used for operating pressures above 3,000 psi
Pressure [Max] 5000 psi
Port T Pressure Rating 1000 psi
Tank Port Rating 1000
Response Time 18 to 25 ms
Mounting Subplate/Manifold Mount
Cycle Rate [Max] N/A
Overrides No Overrides
AC/DC AC
Coil Type ISO 4400 (Din 43650) Connector
Mechanical Options None
Actuator Type Solenoid
Seal Material Buna-N
Model No. DG4S4-016A-U-B-60
Temperature Range [Min] 68 °F
Solenoid Single
Pressure Port Check Valve Pressure N/A
Pilot/Drain None
Indicator Lights No
Spool Code 6
Crossover P Blocked, A or B to T
Pilot Valve Type N/A
Valve Type Standard-Duty
Compatible Fluids Petroleum Oil
Flow Direction Code 4
Electrical Connection DIN 43650
Body Material Gray Iron
Rated Flow [Max] 24 gal/min
Response Type Standard Response
Coil Rating Code B
Operation Solenoid Operated
Design No. 60
Leakage Standard Performance
Mechanical Options Code None
Fluid Cleanliness 19/17/14 micron
Actuation Identification Solenoid B
Coil Type Code U
Spool Spring Arrangement Code A
Temperature Range [Max] 122 °F
Electrical Options None
Port Restrictor Plugs None
Surge Suppressor/Damper None
Performance Standard Performance
Center Position P Blocked, A & B to T
Function 2-Position Spring Offset
Electrical Options Code None
No. of Stages Single Stage
NFPA Size D05
Reducer Module N/A
Voltage & Frequency 110/120 VAC - 50/60 Hz
Manual Override Plain Override
Weight 10.0 LB