Vickers by Danfoss02-126360

02-126360

Vickers D05 Solenoid Valve
Item #101974088
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered, Double End Function
Vickers by Danfoss02-126360
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered, Double End Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Model No. DG4S4-016C-U-D-60
AC/DC AC
Manual Override Plain Override
No. of Stages Single Stage
Response Type Standard Response
Actuation Identification Solenoid A, Solenoid B
Pilot/Drain None
Temperature Range [Min] 68 °F
Indicator Lights No
Solenoid Double
Center Position P Blocked, A & B to T
Function 3-Position Spring Centered, Double End
Spool Code 6
Electrical Connection DIN 43650
Leakage Standard Performance
Coil Type Code U
Performance Standard Performance
Flow Direction Code 4
Voltage & Frequency 220/240 VAC - 50/60 Hz
Crossover P Blocked, A or B to T
Operation Solenoid Operated
Reducer Module N/A
Spool Spring Arrangement Code C
Tank Port Rating 1000
Pilot Valve Type N/A
Compatible Fluids Petroleum Oil
Design No. 60
Electrical Options Code None
Mechanical Options Code None
Response Time 20 to 40 ms
Pressure [Max] 5000 psi
Mounting Subplate/Manifold Mount
Valve Type Standard-Duty
Temperature Range [Max] 122 °F
Overrides No Overrides
Port T Pressure Rating 1000 psi
Surge Suppressor/Damper None
Cycle Rate [Max] N/A
Body Material Gray Iron
Coil Rating Code D
Actuator Type Solenoid
Mechanical Options None
Port Restrictor Plugs None
Pressure Port Check Valve Pressure N/A
Coil Type ISO 4400 (Din 43650) Connector
Electrical Options None
Rated Flow [Max] 24 gal/min
Fluid Cleanliness 19/17/14 micron
NFPA Size D05
Seal Material Buna-N
Weight 10.0 LB