Vickers by Danfoss02-126302

02-126302

Vickers D05 Solenoid Valve
Item #101948904
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-126302
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Each installation should be designed so that the heated section of the heater is totally immersed at all times to avoid heater failure and/or possible damage to the fluid in the tank
Coil Type Flying Leads
Pilot/Drain None
Model No. DG4S4W-016A-B-60
Fluid Cleanliness 19/17/14 micron
Spool Code 6
Electrical Options None
AC/DC AC
Pilot Valve Type N/A
Operation Solenoid Operated
Coil Rating Code B
Body Material Gray Iron
Performance Standard Performance
Cycle Rate [Max] N/A
Leakage Standard Performance
Temperature Range [Max] 122 °F
NFPA Size D05
Mechanical Options None
Seal Material Buna-N
Manual Override Plain Override
Surge Suppressor/Damper None
Mounting Subplate/Manifold Mount
Reducer Module N/A
Port Restrictor Plugs None
Actuator Type Solenoid
Temperature Range [Min] 68 °F
Indicator Lights Yes
Electrical Connection KU W/ Deutsch Connector
Design No. 60
Pressure Port Check Valve Pressure N/A
No. of Stages Single Stage
Tank Port Rating 1000
Function 2-Position Spring Offset
Response Time 18 to 25 ms
Response Type Standard Response
Mechanical Options Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Spring Arrangement Code A
Actuation Identification Solenoid B
Port T Pressure Rating 1000 psi
Solenoid Single
Electrical Options Code W
Rated Flow [Max] 24 gal/min
Coil Type Code None
Crossover P Blocked, A or B to T
Overrides No Overrides
Flow Direction Code 4
Valve Type Standard-Duty
Pressure [Max] 5000 psi
Center Position P Blocked, A & B to T
Compatible Fluids Petroleum Oil
Weight 10.0 LB