Vickers by Danfoss02-119498

02-119498

Vickers D05 Solenoid Valve
Item #101955172
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-119498
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Must be mounted on the driven shaft
Actuator Type Solenoid
Tank Port Rating 1000
Electrical Options Code L
Response Type Standard Response
Function 3-Position Spring Centered
Center Position P Blocked, A & B to T
Reducer Module N/A
Performance Standard Performance
Operation Solenoid Operated
Flow Direction Code 4
Mechanical Options None
Coil Type Flying Leads
Overrides No Overrides
Body Material Gray Iron
Manual Override Plain Override
Spool Spring Arrangement Code C
AC/DC AC
Pilot/Drain None
Temperature Range [Min] 68 °F
Mechanical Options Code None
Spool Code 33
Electrical Options None
Crossover P Blocked, A or B to T
Indicator Lights Yes
Pressure Port Check Valve Pressure N/A
Rated Flow [Max] 24 gal/min
Model No. DG4S4L-0133C-B-60
Port T Pressure Rating 1000 psi
Valve Type Standard-Duty
Seal Material Buna-N
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plugs None
Surge Suppressor/Damper None
Solenoid Double
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure [Max] 3600 psi
Pilot Valve Type N/A
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Max] 122 °F
Coil Type Code None
Design No. 60
Cycle Rate [Max] N/A
Response Time 20 to 40 ms
Compatible Fluids Petroleum Oil
NFPA Size D05
Coil Rating Code B
Electrical Connection Lead Wires w/o Terminal Box
Leakage Standard Performance
No. of Stages Single Stage
Mounting Subplate/Manifold Mount
Weight 10.0 LB