Vickers D03 Solenoid Valve

02-110417

Vickers D03 Solenoid Valve
Item #101970074
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Reducer Module No
Manual Override Plain Override
Solenoid Double
Electrical Options None
Coil Type ISO 4400
Seal Material Buna-N
Pilot Valve Type N/A
Spool Spring Arrangement Code C
Temperature Range [Max] 158 °F
Actuator Type Solenoid
Surge Suppressor/Damper None
Pressure [Max] 5000 psi
Compatible Fluids Petroleum Oil
Response Type Standard Response
Port T Code 6
Solenoid Indicator Lights Code None
Function 3-Position Spring Centered
Electrical Connector Code None
Spool Code 6
Mounting Subplate/Manifold Mount
Solenoid Energization Code None
Coil Rating Code BL
Operation Solenoid Operated
Center Position P Blocked, A & B to T
Rated Flow [Max] 20 gal/min
Fluid Cleanliness 19/17/14 micron
Valve Type High-Performance
No. of Stages Single Stage
Electrical Connection DIN 43650
Manual Override Option Code None
AC/DC AC
Model No. DG4V 3 6C M U BL6 60
Spool Indicator Switch Code None
Pilot/Drain None
Tank Port Rating 3046
Body Material Gray Iron
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Type Code U
Spool Shift Timing N/A
Port T Pressure Rating 3000 psi
Solenoid Code BL
Indicator Lights No
Response Time 15 to 23 ms
Port Restrictor Plug Code None
Performance High Performance
Temperature Range [Min] -4 °F
Actuation Identification Solenoid A, Solenoid B
Port Restrictor Plugs None
Housing Code None
Crossover P Blocked, A or B to T
Cycle Rate [Max] N/A
EN Code None
Overrides No Overrides
Design No. 60
Function Code 6
Surge Suppressor/Damper Code None
NFPA Size D03
Mechanical Options None
Leakage Standard Performance
Pressure Port Check Valve Pressure N/A
Weight 5.0 LB