Vickers D03 Solenoid Valve

02-110292

Vickers D03 Solenoid Valve
Item #101955158
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Electrical Options None
Solenoid Energization Code None
Overrides No Overrides
Solenoid Single
Design No. 60
Coil Type ISO 4400
Port T Code 5
Spool Indicator Switch Code None
Surge Suppressor/Damper Code None
Electrical Connection DIN 43650
Function 2-Position Spring Offset, End To Center, Left Hand Build
Seal Material Buna-N
Response Type Standard Response
Port Restrictor Plugs None
Temperature Range [Min] -4 °F
Valve Type Standard-Duty
Coil Type Code U
Pilot/Drain None
Model No. DG4V-3S-0BL-M-U-B5-60
Pilot Valve Type N/A
Actuator Type Solenoid
Pressure [Max] 5000 psi
Mounting Subplate/Manifold Mount
Reducer Module No
Port T Pressure Rating 1500 psi
Spool Code 0
Tank Port Rating 1450
Electrical Connector Code None
Mechanical Options None
Temperature Range [Max] 158 °F
Leakage Standard Performance
Solenoid Code B
Fluid Cleanliness 19/17/14 micron
Coil Rating Code B
Body Material Gray Iron
Function Code 0
Pressure Port Check Valve Pressure N/A
Center Position All Ports Open
Performance Standard Performance
Spool Spring Arrangement Code B
Response Time 18 to 32 ms
Crossover All Ports Open
Actuation Identification Solenoid A
Cycle Rate [Max] N/A
Indicator Lights No
Manual Override Plain Override
Operation Solenoid Operated
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Shift Timing N/A
Rated Flow [Max] 10 gal/min
Manual Override Option Code None
NFPA Size D03
No. of Stages Single Stage
Solenoid Indicator Lights Code None
AC/DC AC
Compatible Fluids Petroleum Oil
EN Code None
Housing Code None
Surge Suppressor/Damper None
Port Restrictor Plug Code None
Weight 5.0 LB