Vickers D03 Solenoid Valve

02-110292

Vickers D03 Solenoid Valve
Item #101955158
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End To Center, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Coil Rating Code B
Port T Code 5
Electrical Options None
Spool Spring Arrangement Code B
Solenoid Single
Fluid Cleanliness 19/17/14 micron
Actuator Type Solenoid
Spool Code 0
Mounting Subplate/Manifold Mount
Mechanical Options None
Response Type Standard Response
Solenoid Energization Code None
Spool Shift Timing N/A
Body Material Gray Iron
Port T Pressure Rating 1500 psi
Electrical Connection DIN 43650
Cycle Rate [Max] N/A
Pressure [Max] 5000 psi
Port Restrictor Plugs None
Spool Indicator Switch Code None
Temperature Range [Min] -4 °F
Operation Solenoid Operated
Temperature Range [Max] 158 °F
Housing Code None
Leakage Standard Performance
Valve Type Standard-Duty
Overrides No Overrides
Reducer Module No
Surge Suppressor/Damper None
Port Restrictor Plug Code None
Response Time 18 to 32 ms
Performance Standard Performance
Function 2-Position Spring Offset, End To Center, Left Hand Build
Compatible Fluids Petroleum Oil
Actuation Identification Solenoid A
EN Code None
Tank Port Rating 1450
Crossover All Ports Open
Solenoid Code B
Pilot/Drain None
Manual Override Plain Override
Model No. DG4V-3S-0BL-M-U-B5-60
Rated Flow [Max] 10 gal/min
Seal Material Buna-N
Voltage & Frequency 110/120 VAC - 50/60 Hz
Indicator Lights No
AC/DC AC
Pilot Valve Type N/A
Solenoid Indicator Lights Code None
Pressure Port Check Valve Pressure N/A
Coil Type Code U
Surge Suppressor/Damper Code None
Center Position All Ports Open
Electrical Connector Code None
Design No. 60
NFPA Size D03
Coil Type ISO 4400
Manual Override Option Code None
Function Code 0
No. of Stages Single Stage
Weight 5.0 LB