Vickers D03 Solenoid Valve

02-110213

Vickers D03 Solenoid Valve
Item #101953991
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Function Code 6
Pilot/Drain None
Housing Code W
Performance Standard Performance
Fluid Cleanliness 19/17/14 micron
Electrical Connection No Connector
Compatible Fluids Petroleum Oil
Model No. DG4V 3S 6C M FW B5 60 P08
Solenoid Indicator Lights Code None
Surge Suppressor/Damper None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port Restrictor Plugs 0.8 mm Diameter - P Port
Manual Override Option Code None
Spool Code 6
Valve Type Standard-Duty
Electrical Options None
Seal Material Buna-N
Operation Solenoid Operated
Spool Indicator Switch Code None
Electrical Connector Code None
Port Restrictor Plug Code P08
Leakage Standard Performance
No. of Stages Single Stage
Temperature Range [Max] 158 °F
Overrides No Overrides
Mechanical Options None
Coil Type Code F
Coil Rating Code B
Port T Code 5
Spool Spring Arrangement Code C
Response Type Standard Response
Tank Port Rating 1450
Design No. 60
Solenoid Code B
Center Position P Blocked, A & B to T
Function 3-Position Spring Centered
Temperature Range [Min] -4 °F
Body Material Gray Iron
Actuator Type Solenoid
Solenoid Energization Code None
Solenoid Double
Port T Pressure Rating 1500 psi
Cycle Rate [Max] N/A
Spool Shift Timing N/A
Actuation Identification Solenoid A, Solenoid B
Mounting Subplate/Manifold Mount
Voltage & Frequency 110/120 VAC - 50/60 Hz
Indicator Lights No
Response Time 18 to 32 ms
Manual Override Plain Override
Reducer Module No
EN Code None
Pressure [Max] 5000 psi
AC/DC AC
Surge Suppressor/Damper Code None
Rated Flow [Max] 10 gal/min
Crossover P Blocked, A or B to T
NFPA Size D03
Pilot Valve Type N/A
Pressure Port Check Valve Pressure N/A
Weight 5.0 LB