Vickers D03 Solenoid Valve

02-110023

Vickers D03 Solenoid Valve
Item #101970070
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Surge Suppressor/Damper None
Surge Suppressor/Damper Code None
Pilot/Drain None
Overrides No Overrides
Function Code 2
Solenoid Indicator Lights Code None
Temperature Range [Max] 158 °F
Port Restrictor Plugs None
Solenoid Single
Leakage Standard Performance
Model No. DG4V-3-2B-M-FW-B6-60
Electrical Options None
Pressure [Max] 5000 psi
Crossover All Ports Blocked
Seal Material Buna-N
No. of Stages Single Stage
Mounting Subplate/Manifold Mount
Compatible Fluids Petroleum Oil
Coil Rating Code B
AC/DC AC
Spool Spring Arrangement Code B
Pilot Valve Type N/A
Rated Flow [Max] 20 gal/min
Manual Override Option Code None
Port Restrictor Plug Code None
Tank Port Rating 3046
Manual Override Plain Override
EN Code None
Port T Code 6
NFPA Size D03
Port T Pressure Rating 3000 psi
Solenoid Code B
Performance High Performance
Valve Type High-Performance
Response Time 15 to 23 ms
Reducer Module No
Cycle Rate [Max] N/A
Indicator Lights No
Spool Code 2
Housing Code W
Function 2-Position Spring Offset, End to Center
Voltage & Frequency 110/120 VAC - 50/60 Hz
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Solenoid Energization Code None
Body Material Gray Iron
Actuator Type Solenoid
Actuation Identification Solenoid B
Mechanical Options None
Coil Type Code F
Response Type Standard Response
Fluid Cleanliness 19/17/14 micron
Center Position All Ports Blocked
Design No. 60
Temperature Range [Min] -4 °F
Electrical Connector Code None
Operation Solenoid Operated
Pressure Port Check Valve Pressure N/A
Spool Indicator Switch Code None
Electrical Connection No Connector
Spool Shift Timing N/A
Weight 5.0 LB