Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Full Load rpm
1760 rpm
C Dimension
16 in
Brake Feature
No
Washdown Duty
No
Motor Shaft Length
2 3/4 in
Poles
4
Full Load Efficiency
89.5 %
Rotation
R
Mounting Style
F-1
BALD Family Names
Premium Efficient, C-Face, Nema Premium™
Phase
Three Phase
Full Load Pf
80
Product Line
N
RefPicture
VEM
Mult. Sym.
L1
RPM
1800 rpm
Voltage
575
Full Load Amps
3.2
Service Factor
1.15
VoltCode
H
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Frame Size
180TC
Mounting
C-Face - Less Base
Enclosure
TEFC
Design
B
Hz
60 Hz
Useable at 208V
No
Drive End Bearing
6206
Frame Material
Cast Iron
Voltage Rating
575
Type
0628M
Frame
182TC
Open End Bearing
6205
Motor Shaft Size
1 1/8 in
Efficiency Group
Premium Efficient
Motor Application
General Purpose
Weight
100.0 LB
EAN or UPC
781568154144
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back