Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Enclosure
XPFC
Frame
364T
Product Line
RG
VoltCode
U
Brake Feature
No
Voltage
190/380/230/460
Useable at 208V
No
Service Factor
1
Full Load Efficiency
94.5 %
Rotation
R
BALD Family Names
Premium Efficient, Explosion Proof
Enclosure Designation
XPFC - Explosion Proof Fan Cooled
RPM
1800 rpm, 1500 rpm
Full Load Amps
69
Poles
4
Mounting
Rigid Base
Drive End Bearing
6313
Mult. Sym.
L1
Mounting Style
F-1
Frame Size
Shaft Input, Not a C-Face
Washdown Duty
No
Open End Bearing
6312
RefPicture
XPCI
Efficiency Group
Premium Efficient
Hz
60 Hz, 50 Hz
Design
B
Full Load Pf
86
Full Load rpm
1475 rpm, 1780 rpm
Motor Shaft Size
2 3/8 in
C Dimension
33 1/4 in
Voltage Rating
190, 460, 230, 380
Motor Application
Explosion Proof
Motor Shaft Length
5 7/8 in
Phase
Three Phase
Type
X1462M
Weight
989.0 LB
EAN or UPC
781568296035
NEMA Premium
My Applied Catalog