Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Phase
Three Phase
Washdown Duty
No
Mounting
Rigid Base
Enclosure Designation
XPFC - Explosion Proof Fan Cooled
RPM
1800 rpm, 1500 rpm
Frame Size
Shaft Input, Not a C-Face
Motor Application
Explosion Proof
Drive End Bearing
6309
Enclosure
XPFC
Useable at 208V
No
Mounting Style
F-1
Full Load Amps
24
Motor Shaft Length
4 in
Hz
60 Hz, 50 Hz
Voltage Rating
190, 460, 230, 380
BALD Family Names
Premium Efficient, Explosion Proof
Brake Feature
No
RefPicture
XPCI
Type
X0952M
Product Line
RG
Design
B
Mult. Sym.
L1
Rotation
R
Full Load Pf
84
Motor Shaft Size
1 5/8 in
Open End Bearing
6208
Frame
256T
Poles
4
Efficiency Group
Premium Efficient
VoltCode
U
Voltage
190/380/230/460
Full Load Efficiency
93 %
C Dimension
25 1/2 in
Full Load rpm
1465 rpm, 1765 rpm
Service Factor
1
Weight
399.0 LB
EAN or UPC
781568295984
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back