Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
C Dimension
32.84 in
Full Load Pf
79
Mult. Sym.
L1
Washdown Duty
No
Open End Bearing
6312
Frame
364T
Product Line
RG
Poles
6
Mounting Style
F-1
RefPicture
EMTECI
Frame Size
Shaft Input, Not a C-Face
Frame Material
Cast Iron
Brake Feature
No
Full Load rpm
1185 rpm
Enclosure
TEFC
Efficiency Group
Premium Efficient
Voltage
230/460
BALD Family Names
Premium Efficient, Nema Premium™
VoltCode
F
Type
1468M
RPM
1200 rpm
Full Load Efficiency
94.1 %
Motor Application
General Purpose
Mounting
Rigid Base
Voltage Rating
460, 230
C Face Kit
14-1704
Hz
60 Hz
Substitute Motor
M4308T
Epact Nominal Full Load Efficiency
93 %
Motor Shaft Size
2 3/8 in
Motor Shaft Length
5 7/8 in
Phase
Three Phase
Design
B
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Rotation
R
Drive End Bearing
6313
Useable at 208V
No
Service Factor
1.15
Full Load Amps
50.5
Weight
908.0 LB
EAN or UPC
781568103418
NEMA Premium
My Applied Catalog
We're here for you