Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Frame Size
Shaft Input, Not a C-Face
Motor Shaft Size
1 7/8 in
C Face Kit
12-1105
RPM
3600 rpm
VoltCode
H
Voltage
575
Voltage Rating
575
Full Load Pf
91
Full Load rpm
3540 rpm
Poles
2
Useable at 208V
No
Motor Application
General Purpose
Full Load Amps
43.6
Phase
Three Phase
Drive End Bearing
6312
Enclosure
TEFC
Service Factor
1.15
Full Load Efficiency
94.1 %
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Washdown Duty
No
Product Line
RG
Type
1252M
Mult. Sym.
L1
Frame
326TS
Motor Shaft Length
3 3/4 in
C Dimension
28.78 in
Mounting
Rigid Base
Mounting Style
F-1
Efficiency Group
Premium Efficient
Open End Bearing
6311
Brake Feature
No
Substitute Motor
M4114T-5
Rotation
R
BALD Family Names
Premium Efficient, Nema Premium™
Frame Material
Cast Iron
RefPicture
EMTECI
Hz
60 Hz
Design
B
Weight
578.0 LB
EAN or UPC
781568139141
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back