Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Substitute Motor
M4108T-5
Efficiency Group
Premium Efficient
Mounting
Rigid Base
Motor Application
General Purpose
Washdown Duty
No
Voltage Rating
575
Hz
60 Hz
Open End Bearing
6208
Poles
2
Full Load Pf
92
Rotation
R
Brake Feature
No
Mounting Style
F-1
BALD Family Names
Premium Efficient, Nema Premium™
Full Load Efficiency
93 %
Motor Shaft Length
3 1/4 in
C Face Kit
10-1305
RefPicture
EMTECI
Full Load Amps
26.2
Full Load rpm
3520 rpm
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Design
A
C Dimension
26.39 in
Drive End Bearing
6311
Voltage
575
Product Line
RG
VoltCode
H
Enclosure
TEFC
Frame
286TS
Useable at 208V
No
Frame Size
Shaft Input, Not a C-Face
Frame Material
Cast Iron
Type
0954M
RPM
3600 rpm
Mult. Sym.
L1
Motor Shaft Size
1 5/8 in
Phase
Three Phase
Service Factor
1.15
Weight
418.0 LB
EAN or UPC
781568139127
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back