Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Enclosure
TEFC
Open End Bearing
6309
Voltage Rating
460, 230
Full Load rpm
1180 rpm
Efficiency Group
Premium Efficient
Substitute Motor
EM4102T
Motor Shaft Size
1 7/8 in
Frame Material
Cast Iron
VoltCode
E1
BALD Family Names
Premium Efficient, Nema Premium™
Useable at 208V
Yes
Service Factor
1.15
Voltage
230/460
Epact Nominal Full Load Efficiency
90.2 %
Mounting
Rigid Base
Frame
284T
Full Load Amps
18.7
C Dimension
27.76 in
Mult. Sym.
L1
C Face Kit
10-1305
Mounting Style
F-1
RPM
1200 rpm
Full Load Efficiency
92.4 %
Motor Shaft Length
4 5/8 in
Poles
6
Rotation
R
RefPicture
EMTECI
Hz
60 Hz
Phase
Three Phase
Brake Feature
No
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Drive End Bearing
6311
Product Line
RG
Type
1054M
Motor Application
General Purpose
Frame Size
Shaft Input, Not a C-Face
Washdown Duty
No
Design
B
Full Load Pf
81
Weight
391.0 LB
EAN or UPC
781568103029
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back