Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Useable at 208V
Yes
Motor Application
General Purpose
Full Load Amps
5
Motor Shaft Size
1 3/8 in
Full Load Pf
64
Voltage Rating
460, 230
Washdown Duty
No
BALD Family Names
Premium Efficient, Nema Premium™
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
RefPicture
EM3708T
Mounting
Rigid Base
C Dimension
17.94 in
Frame
213T
Hz
60 Hz
Motor Shaft Length
3 3/8 in
C Face Kit
37-1304
Mult. Sym.
L1
Drive End Bearing
6307
Type
3736M
RPM
1200 rpm
Enclosure
TEFC
Voltage
230/460
Frame Size
Shaft Input, Not a C-Face
Full Load rpm
1160 rpm
Epact Nominal Full Load Efficiency
87.5 %
Poles
6
Design
B
Frame Material
Steel
Open End Bearing
6206
Product Line
RG
Full Load Efficiency
89.5 %
Brake Feature
No
Service Factor
1.15
Phase
Three Phase
Efficiency Group
Premium Efficient
Mounting Style
F-1
Rotation
R
VoltCode
E1
Weight
134.0 LB
EAN or UPC
781568139011
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back