Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Epact Nominal Full Load Efficiency
84 %
Mounting
Rigid Base
C Face Kit
35-8764
Hz
60 Hz
Enclosure
OPSB
Full Load Pf
77
Drive End Bearing
6205
Phase
Three Phase
Product Line
RG
Voltage
208-230/460
Open End Bearing
6203
BALD Family Names
Premium Efficient, Nema Premium™
Poles
4
Motor Shaft Size
7/8 in
Full Load rpm
1740 rpm
VoltCode
E
Mounting Style
F-1
RPM
1800 rpm
Service Factor
1.15
Brake Feature
No
Motor Application
General Purpose
Voltage Rating
460, 230, 208
Substitute Motor
M3154T
Full Load Efficiency
86.5 %
Mult. Sym.
L1
Rotation
R
Useable at 208V
Yes
Design
B
Washdown Duty
No
Efficiency Group
Premium Efficient
RefPicture
EMDP
Type
3526M
Full Load Amps
2.1
Frame Size
Shaft Input, Not a C-Face
Enclosure Designation
OPSB - Open Slotted Band
Frame
145T
Frame Material
Steel
Motor Shaft Length
2 1/4 in
Weight
37.0 LB
EAN or UPC
781568104231