Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Motor Shaft Length
5 1/4 in
RPM
1200 rpm
RefPicture
EMDP
Motor Application
General Purpose
C Face Kit
42-1300
Enclosure
OPSB
Product Line
RG
Rotation
R
Phase
Three Phase
Motor Shaft Size
2 1/8 in
VoltCode
E1
Voltage
230/460
Frame Size
Shaft Input, Not a C-Face
Full Load rpm
1180 rpm
Mounting
Rigid Base
Frame
326T
Full Load Efficiency
93.6 %
Epact Nominal Full Load Efficiency
92.4 %
Poles
6
Type
4268M
Washdown Duty
No
Frame Material
Steel
Full Load Amps
37
Efficiency Group
Premium Efficient
Useable at 208V
Yes
Hz
60 Hz
BALD Family Names
Premium Efficient, Nema Premium™
Mult. Sym.
L1
Full Load Pf
81
Mounting Style
F-1
Open End Bearing
6311
Brake Feature
No
C Dimension
27.69 in
Voltage Rating
460, 230
Substitute Motor
M2536T
Design
B
Drive End Bearing
6312
Enclosure Designation
OPSB - Open Slotted Band
Service Factor
1.15
Weight
463.0 LB
EAN or UPC
781568105085
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back