Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
RPM
3600 rpm
Motor Shaft Length
3 1/4 in
Design
B
Frame Size
Shaft Input, Not a C-Face
RefPicture
EMDP
Rotation
R
Frame Material
Steel
Substitute Motor
M2534T
Epact Nominal Full Load Efficiency
91 %
C Face Kit
40-1400
Frame
284TS
Drive End Bearing
6311
VoltCode
F
Product Line
RG
Useable at 208V
No
Washdown Duty
No
Open End Bearing
6309
Motor Shaft Size
1 5/8 in
Service Factor
1.15
Enclosure Designation
OPSB - Open Slotted Band
Type
4040M
Mounting
Rigid Base
BALD Family Names
Premium Efficient, Nema Premium™
Brake Feature
No
Phase
Three Phase
Full Load Pf
89
Hz
60 Hz
Full Load Amps
34
Voltage Rating
460, 230
Voltage
230/460
Motor Application
General Purpose
C Dimension
22.44 in
Enclosure
OPSB
Full Load Efficiency
93.6 %
Mounting Style
F-1
Efficiency Group
Premium Efficient
Poles
2
Full Load rpm
3530 rpm
Mult. Sym.
L1
Weight
308.0 LB
EAN or UPC
781568105030
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back