Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Mult. Sym.
L1
Washdown Duty
No
Enclosure Designation
OPSB - Open Slotted Band
Drive End Bearing
6311
Frame
286T
Motor Application
General Purpose
Voltage
230/460
Hz
60 Hz
Mounting Style
F-1
Service Factor
1.15
VoltCode
E1
C Face Kit
40-1400
Substitute Motor
M2528T
Epact Nominal Full Load Efficiency
91 %
Frame Size
Shaft Input, Not a C-Face
Enclosure
OPSB
RefPicture
EMDP
Poles
6
Full Load Pf
80
Frame Material
Steel
Design
B
Full Load Efficiency
92.4 %
Type
4056M
Product Line
RG
Brake Feature
No
Mounting
Rigid Base
Useable at 208V
Yes
Voltage Rating
460, 230
RPM
1200 rpm
Motor Shaft Length
4 5/8 in
Rotation
R
Efficiency Group
Premium Efficient
Motor Shaft Size
1 7/8 in
Phase
Three Phase
BALD Family Names
Premium Efficient, Nema Premium™
Full Load Amps
26
Full Load rpm
1180 rpm
Open End Bearing
6309
Weight
372.0 LB
EAN or UPC
781568104941
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back