Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Washdown Duty
No
Open End Bearing
6312
Type
1482M
RPM
1800 rpm
Motor Application
Severe Duty
Motor Shaft Size
2 3/8 in
Useable at 208V
No
Mounting Style
F-1
Voltage
460
VoltCode
G
Rotation
R
Design
B
Voltage Rating
460
Efficiency Group
Standard Efficient
Full Load Efficiency
95.4 %
HP [Min]
75
C Dimension
32.84 in
Mounting
Foot Mounted
Frame
365T
Drive End Bearing
6313
Full Load rpm
1780 rpm
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Poles
4
Enclosure
Totally Enclosed
Product Line
RG
Service Factor
1.15
Phase
Three Phase
Hz
60 Hz
RefPicture
ECP03
Brake Feature
No
Epact Nominal Full Load Efficiency
94.1 %
Full Load Amps
86.5
Motor Shaft Length
5 7/8 in
Frame Material
Cast Iron
Full Load Pf
85
C Face Kit
14-1704
Mult. Sym.
L1
Model
841 XL
Frame Size
365T
Weight
971.0 LB
EAN or UPC
781568196670
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back