Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Useable at 208V
No
Type
1876M
Motor Shaft Length
8 1/2 in
Full Load Efficiency
95.4 %
RPM
1800 rpm
Efficiency Group
Standard Efficient
HP [Min]
125
Product Line
RG
Washdown Duty
No
Rotation
R
Model
XEX
Voltage Rating
460
Poles
4
Service Factor
1.15
Frame Material
Cast Iron
Frame Size
444T
C Dimension
44.18 in
Mult. Sym.
LS
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Brake Feature
No
Mounting
Foot Mounted
Design
B
Phase
Three Phase
Open End Bearing
6314
C Face Kit
18-1302
Voltage
460
Motor Shaft Size
3 3/8 in
Drive End Bearing
6319
Full Load Amps
139
Epact Nominal Full Load Efficiency
94.5 %
Frame
444T
Motor Application
Severe Duty
Mounting Style
F-1
Full Load rpm
1780 rpm
RefPicture
CRUSH
Enclosure
Totally Enclosed
Full Load Pf
88
VoltCode
G
Hz
60 Hz
Weight
1781.0 LB
EAN or UPC
781568107706
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back