Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Service Factor
1.15
Phase
Three Phase
Type
18168M
Full Load Efficiency
95.8 %
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
RPM
1800 rpm
Hz
60 Hz
Washdown Duty
No
Product Line
RG
Enclosure
Totally Enclosed
Model
XEX
Frame
449T
Design
B
Substitute Motor
ECP44354T-4
VoltCode
G
Poles
4
Motor Shaft Length
8 1/2 in
Frame Material
Cast Iron
Motor Application
Severe Duty
Drive End Bearing
6319
Full Load Amps
275
Brake Feature
No
Useable at 208V
No
Full Load rpm
1785 rpm
Frame Size
449T
Mounting Style
F-1
Mounting
Foot Mounted
Efficiency Group
Standard Efficient
Open End Bearing
6314
C Dimension
52.65 in
HP [Min]
250
Full Load Pf
90
Rotation
R
Voltage Rating
460
RefPicture
CRUSH
Motor Shaft Size
3 3/8 in
Voltage
460
Mult. Sym.
LS
Weight
2972.0 LB
EAN or UPC
781568136966
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back