Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Enclosure
Totally Enclosed
Service Factor
1.15
Motor Shaft Size
2 7/8 in
Full Load Efficiency
95.4 %
Frame Size
405T
Model
XEX
Full Load Pf
90
Voltage
460
Frame
405T
Frame Material
Cast Iron
Mult. Sym.
LS
Voltage Rating
460
Poles
4
C Face Kit
16-1704
Motor Application
Severe Duty
Washdown Duty
No
Useable at 208V
No
Product Line
RG
Brake Feature
No
VoltCode
G
Substitute Motor
CP4400T-4
RefPicture
CRUSH
Motor Shaft Length
7 1/4 in
Type
1684M
Full Load rpm
1780 rpm
Mounting Style
F-1
Mounting
Foot Mounted
Open End Bearing
6313
C Dimension
36.88 in
Rotation
R
RPM
1800 rpm
Epact Nominal Full Load Efficiency
94.5 %
Drive End Bearing
6316
HP [Min]
100
Hz
60 Hz
Efficiency Group
Standard Efficient
Phase
Three Phase
Design
B
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Full Load Amps
109
Weight
1296.0 LB
EAN or UPC
781568107676
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back