Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Service Factor
1.15
Hz
60 Hz
Motor Shaft Size
1 7/8 in
HP [Min]
15
Useable at 208V
No
C Dimension
27.57 in
Enclosure
Totally Enclosed
Voltage
460
Product Line
RG
Rotation
R
Mounting
Foot Mounted
Full Load Amps
18.7
Frame Size
284T
C Face Kit
10-1305
Motor Shaft Length
4 5/8 in
Substitute Motor
CP4100T-4
Motor Application
Severe Duty
Efficiency Group
Standard Efficient
Poles
6
Model
XEX
Type
1054M
Frame
284T
Mounting Style
F-1
RefPicture
ECP03
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Full Load Efficiency
92.4 %
Washdown Duty
No
Drive End Bearing
6311
Mult. Sym.
L1
Phase
Three Phase
RPM
1200 rpm
Design
B
Full Load rpm
1180 rpm
Frame Material
Cast Iron
Voltage Rating
460
VoltCode
G
Full Load Pf
81
Epact Nominal Full Load Efficiency
90.2 %
Open End Bearing
6309
Brake Feature
No
Weight
448.0 LB
EAN or UPC
781568136720
NEMA Premium