Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Drive End Bearing
6307
C Dimension
19.91 in
BALD Family Names
Premium Efficient, Explosion Proof
Voltage
190/380/230/460
RefPicture
EM7064T
Mounting Style
F-1
Motor Shaft Size
1 1/8 in
Motor Shaft Length
3 in
Mounting
Rigid Base
Motor Application
Explosion Proof
Poles
4
Useable at 208V
No
Mult. Sym.
L1
Open End Bearing
6206
Frame Size
Shaft Input, Not a C-Face
Efficiency Group
Premium Efficient
Design
A
Frame
215T
Service Factor
1
Rotation
R
Full Load Amps
12.5
Washdown Duty
No
RPM
1800 rpm, 1500 rpm
Product Line
RG
Voltage Rating
190, 460, 230, 380
Full Load Pf
83
Hz
60 Hz, 50 Hz
Full Load rpm
1460 rpm, 1760 rpm
VoltCode
U
Brake Feature
No
Type
X0750M
Enclosure
XPFC
Phase
Three Phase
Enclosure Designation
XPFC - Explosion Proof Fan Cooled
Full Load Efficiency
91 %
Weight
252.0 LB
EAN or UPC
781568220313
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back