Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Full Load Pf
86
Poles
4
Phase
Three Phase
Enclosure Designation
XPFC - Explosion Proof Fan Cooled
Enclosure
XPFC
Design
B
Full Load Efficiency
94.5 %
Voltage Rating
190, 460, 230, 380
Service Factor
1
Efficiency Group
Premium Efficient
Frame Size
Shaft Input, Not a C-Face
VoltCode
U
Drive End Bearing
6313
BALD Family Names
Premium Efficient, Explosion Proof
Motor Shaft Length
5 7/8 in
Useable at 208V
No
Brake Feature
No
Frame Material
Cast Iron
Full Load Amps
69
Frame
364T
Voltage
190/380/230/460
Motor Shaft Size
2 3/8 in
Product Line
RG
Washdown Duty
No
Type
X1462M
Motor Application
Explosion Proof
Rotation
R
C Dimension
32 1/4 in
Full Load rpm
1475 rpm, 1780 rpm
Open End Bearing
6312
Mult. Sym.
L1
Mounting
Rigid Base
RPM
1800 rpm, 1500 rpm
RefPicture
EM7064T
Hz
60 Hz, 50 Hz
Substitute Motor
M7066T
Mounting Style
F-1
Weight
1016.0 LB
EAN or UPC
781568139288
NEMA Premium