Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Motor Shaft Length
4 5/8 in
BALD Family Names
Premium Efficient, Explosion Proof
Type
X1050M
Mounting Style
F-1
Voltage Rating
190, 460, 230, 380
Full Load Efficiency
93.6 %
Service Factor
1
Motor Application
Explosion Proof
RefPicture
XPCI
Mult. Sym.
L1
RPM
1800 rpm, 1500 rpm
Design
B
Phase
Three Phase
Frame
284T
Enclosure Designation
XPFC - Explosion Proof Fan Cooled
Full Load rpm
1470 rpm, 1780 rpm
Mounting
Rigid Base
Efficiency Group
Premium Efficient
Product Line
RG
Frame Size
Shaft Input, Not a C-Face
Poles
4
VoltCode
U
C Dimension
28.61 in
Hz
60 Hz, 50 Hz
Washdown Duty
No
Enclosure
XPFC
Full Load Pf
82
Open End Bearing
6309
Motor Shaft Size
1 7/8 in
Voltage
190/380/230/460
Useable at 208V
No
Full Load Amps
30.5
Rotation
R
Brake Feature
No
Drive End Bearing
6311
Weight
595.0 LB
EAN or UPC
781568295991
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back