Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Rotation
R
Full Load Amps
18.4
BALD Family Names
Premium Efficient, Nema Premium™
Phase
Three Phase
Open End Bearing
6208
Product Line
RG
Motor Shaft Length
4 in
VoltCode
H
C Face Kit
09-1309
Full Load Pf
89
C Dimension
23.19 in
Design
A
Enclosure
TEFC
Washdown Duty
No
RPM
3600 rpm
Service Factor
1.15
Hz
60 Hz
Frame
256T
Brake Feature
No
Mounting
Rigid Base
Frame Material
Cast Iron
Drive End Bearing
6309
Substitute Motor
M4106T-5
Poles
2
Voltage Rating
575
Mounting Style
F-1
Full Load rpm
3540 rpm
Type
0944M
Mult. Sym.
L1
Full Load Efficiency
92.4 %
RefPicture
EMTECI
Motor Application
General Purpose
Enclosure Designation
TEFC - Totally Enclosed Fan Cooled
Efficiency Group
Premium Efficient
Motor Shaft Size
1 5/8 in
Useable at 208V
No
Frame Size
Shaft Input, Not a C-Face
Voltage
575
Weight
252.0 LB
EAN or UPC
781568139103
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back