Motors misapplied in hazardous environments can cause a fire or explosion, resulting in destruction of property, serious injury or death
Only the end user or a qualified underwriter is to identify and select the proper class, group, division and temperature code motor to meet the requirements of each installation
Service center personnel can advise what listings and approvals motors carry, but cannot evaluate nor recommend what motors may be suitable for use in hazardous environments
Useable at 208V
Yes
Frame Material
Steel
VoltCode
E
Poles
4
Full Load Efficiency
86.5 %
Product Line
RG
Hz
60 Hz
Full Load Pf
82
Frame
145T
Drive End Bearing
6205
RefPicture
EMDP
Enclosure Designation
OPSB - Open Slotted Band
Design
B
Epact Nominal Full Load Efficiency
84 %
Enclosure
OPSB
Brake Feature
No
Mult. Sym.
L1
Motor Shaft Size
7/8 in
Efficiency Group
Premium Efficient
Full Load Amps
2.7
RPM
1800 rpm
C Dimension
13 in
Full Load rpm
1725 rpm
Motor Application
General Purpose
Mounting Style
F-1
Voltage
208-230/460
Open End Bearing
6203
Voltage Rating
460, 230, 208
Mounting
Rigid Base
BALD Family Names
Premium Efficient, Nema Premium™
C Face Kit
35-8764
Frame Size
Shaft Input, Not a C-Face
Motor Shaft Length
2 1/4 in
Rotation
R
Service Factor
1.15
Washdown Duty
No
Phase
Three Phase
Type
3532M
Weight
40.0 LB
EAN or UPC
781568104347
NEMA Premium
My Applied Catalog
We're here for you
with Service Centers across the country - We have your back